Selection Assistance and Guides
LPG Application
Guide The LPG Application Guide demonstrates all of the LPG industry solutions
that Corken products may facilitate. To better help you determine which Corken
LPG is best suited for your needs, click either on the title of the Corken LPG
product or on the stations themselves for more information.
Industrial Pumps
The Hydraulic Selection / Overview Graph is intended to give you an overview
of our hydraulic range as well as aid you in determining which of our pump products
will best fit your current needs. When
reading this graph please keep in mind that the reference liquid is water. Liquids
with viscosities and specific gravities that differ from water will not necessarily
reflect the same flow rates and pressures. Nevertheless, since the purpose of
this graph is to get you going in the right direction, it should prove more than
adequate. Please note that differential
pressure (psi) is provided on the left of the graph while differential head (ft)
is provided on the right. Click on
pump line to obtain more information.
The calculation that ties (ft) to (psi)
together is: Head (ft) =
2.31 x (psi)
Specific Gravity of Water = 1.0
Specific Gravity |